射頻探針
Model 10 (dc to 11 GHz )
 Model 10 (dc to 11 GHz )
  • 規格參數
  • 資料下載


PICOPROBE® MODEL 10

PICOPROBE® MODEL 10 is a multipurpose, high speed, passive probe which can be used for driving as well as receiving signals. The Model 10 consists of a one meter length of flexible 50 ohm coaxial cable terminated by a carefully trimmed SMA on one end and by a miniature, high speed 50 ohm connector, specially developed to receive Model 10 replaceable coaxial probe tips, on the other. The 50 ohm coaxial cable was custom designed for Model 10 to be high speed, yet very flexible, so that moving the cable would not disturb the probe points.

Adaptable for a wide range of applications, the Model 10 uses a variety of special purpose, easily replaceable probe tips. Each probe tip consists of a 1.5 inch long 50 ohm semi-rigid coaxial line, a retaining nut, one or two probe points, and a variety of electrical components tailored to achieve the desired electrical characteristics. To drive or receive signals on 50 ohm circuit points, the Model 10 should be fitted with a probe tip that has two probe points, one for the ground and one for the signal.

Probe points which extend 0.120 inches beyond the 50ohm coaxial probe tip have been designed fordc to 3.5 GHz response and probe points which extend 0.030 inches beyond the probe tip have been designed for dc to 7 GHz response. The longer 0.120 inch tips are more flexible, making them more durable and easier to use than the shorter 0.030 inch style.

To receive signals from high impedance circuit points, Model 10 probe tips with a 250 ohm, 500 ohm, or 5 k ohm input resistance should be used. All have been trimmed to compensate for cable loss and to minimize the need for a short ground. Grounding methods would depend upon the desired frequency response and range from dual probe points to a 6 inch long flexible ground strap. In applications where many circuit points must be accessed and ground is not conveniently located, a flexible ground strap can be substituted for the ground point.

The 250 ohm tip should be used with 0.180 inch long dual probe points to achieve dc to 10 GHz response. The signal will be attenuated by 5:1. The 500 ohm tip should be used either with 0.180 inch long dual probe points to achieve dc to 11 GHz response or with a 2 inch long ground strap to achieve dc to 4 GHz response. The signal will be attenuated by 10:1.

The 5k ohm tip should be used either with 0.180 inch long dual probe points to achieve dc to 5 GHz response, a 2 inch ground strap to achieve dc to 4 GHz response, or a 6 inch ground strap to achieve dc to 2 GHz response. The signal will be attenuated by 100:1.

To drive high impedance circuit points Model 10 probe tips with a 50 ohm terminating resistor should be used.

Model 10 was designed to be attached to any micropositioner for use on any probe station. Simply state the make and model number when ordering and the properly shaped probe will be delivered to you.



MODEL 10 SPECIFICATIONS
50 ohm input impedance mode
Probe Wire Length 0.120 inch 0.030 inch
Frequency Response: dc to 3.5 GHz dc to 7 GHZ
Insertion Loss: 3 dB 3 dB
Return Loss: greater than 10 dB greater than 10 dB
Attenuation: 1:1 1:1



250 ohm input impedance mode
Frequency Response dc to 10 GHz(-3 dB)
Attenuation> 5:1
500 ohm input impedance mode
Frequency Response: dc to 11 GHz(-3 dB)
Attenuation: 10:1


5K ohm input impedance mode
Frequency Response: dc to 5 GHz(-3 dB)
Attenuation: 100:1

Model 10 Replacement Tips
Part Number System
Model
Number
Added Resistance to
50 ohm Coaxial Tip
Outside Diameter of
Probing Wire
Probing Wire
Material
No. of
Probing Wires
Ground
R/L
Space Between
Points
10- 50/30 = no added resistance (50 ohm coax to 0.030" long probe tips) 125=125 micron wire sharpened to approx. 5 microns for tungsten and 25 microns for Pd or BeCu W=Tungsten 1=one signal wire only R=Right
L=Left
Ground on Right or Left side of signal point as seen looking from front to back of Model 10
Spacing between signal and ground points(indicate distance in inches or microns)
10- 50/120 = no added resistance (50 ohm coax to 0.120" long probe tips) 60=60 micron wire sharpened to approx. 3 microns for tungsten and 10 microns for Pd or BeCu Pd=Palladium
Only available in 200 micron diameter with 2.5 micron point radius or 12.5 micron point radius
2=one signal wire and one ground wire
10- 50T = 50 ohm resistor placed between center conductor and shield just before probe tips 35=35 micron wire sharpened to approx. 2 microns(tungsten only) BeCu=Beryllium Copper End Part Number here if "1" is entered
10- 50C =a capacitor placed between center conductor and shield just before probe tips(specify value) 22=22 micron wire sharpened to approx. 1 microns(tungsten only)
10- 250=250 ohm input resistor
attenuates 5:1
10=10 micron wire sharpened to approx. 0.2 microns(tungsten only)
10- 500=500 ohm input resistor
attenuates 10:1
10- 1K=1K ohm input resistor
attenuates 20:1
10- 2.5K=2.5K ohm input resistor
attenuates 50:1
10- 5K=5K ohm input resistor
attenuates 100:1

EXAMPLE:

10-500-60-W-2-R-120 micron – Denotes a Model 10 tip with 500 ohm input resistance, 60 micron probing wires, one signal and one ground wire made of tungsten, the ground is on the right side of the signal wire, and the space between probe points is 120 microns.









推薦產品
主站蜘蛛池模板: 欧洲美女黑人粗性暴交视频 | 亚洲精品av无码重口另类 | 久久蜜臀一区二区三区av | 国产亚洲网曝欧美台湾丝袜 | 韩国一级片视频 | 丰满熟女人妻中文字幕免费 | 成人片黄网站A毛片免费观看 | 中国午夜伦理片 | 老司机带带我免费视频 | 日韩亚洲国产免费 | 色就色综合偷拍区第三十七页 | 图片小说视频一区二区 | 日本激情动作片免费看 | 香蕉免费一区二区三区在 | 亚洲美国产亚洲AV | 精品少妇av一区二区三区 | 国产妇女野外牲一级毛片 | 亚洲国产综合av | 下面一进一出好爽视频 | 无码中文AV有码中文A | 美女18毛片| 顶级欧美熟妇高清xxxxx | 凹凸在线无码免费视频 | 国内大量揄拍人妻精品視頻 | 91aaa国产| 亚洲国产熟妇无码日韩 | 成品片a免费直接观看 | 安眠药扒开女同学双腿玩弄 | 中文字幕在线视频一区二区三区 | 特级无码毛片免费视频尤物 | 91免费观看网站 | 精品1区2区3区4区产品乱码9 | 禁18在线观看免费网站 | 精品久久一区二区三区 | 免费看裸体美女脱了衣服露视频胸 | 欧美一二在线 | 亚洲国产精品久久精品 | 国产精品影视在线 | 中文字幕亚洲综合久久青草 | 欧美一区二区三曲的 | 亚洲AV成人一区二区三区AV |